Performance Parameters
Output and purity
Product
|
Output
(Nm3/h)
|
Purity
(Volume)
|
Pressure barg
EX Cold box
|
Moisture
Dew point
|
GAN
|
2000
|
≤5PPmO2
|
7
|
≤-70℃
|
LIN
|
100L/h
|
≤5PPmO2
|
7
|
≤ -70℃
|
Note: Nm3/h refers to the volume flow at 0℃& 101.3KPa. (The same in the following)
Operation period (duration between two major heating) 12months
Warming and de-riming Time 24 h
Warm starting time for nitrogen 36h
Cold starting time for nitrogen 6 h
Turn down rate 80~100%
Annual available hours: 8760 h/y (365 d x 24 h/d)
Stop for scheduled annual maintenance: 160 h/y
Annual available net production hours: 8600 h/y
Remark: For more details, please send us enquiry.